In-Line, Real-Time Powder Flow & Process Monitoring

Tim Freeman
In-Line, Real-Time Powder Flow & Process Monitoring - Bottles


Innovative technology for in-line real-time powder flow monitoring based on drag force flow measurement offers great potential for efficient monitoring of powder-processing operations.

Most pharmaceuticals are handled in powder form at some point during production, notably those delivered in oral solid dosage form. This makes efficient powder handling and processing essential for competitive drug manufacture. While the process analytical technology (PAT) available for powder processes has advanced considerably over the last decade, there are still areas where the current analytical solution is suboptimal, particularly as the industry embraces continuous manufacture.

DRAG FORCE FLOW MEASUREMENT

The defining features of a sensor for in-line measurement of the instantaneous local forces associated with the movement of powders, granules, or a wet mass, shown in Figure 1, are a hollow cylinder with two optical strain gauges (fiber Bragg gratings, or FBGs), mounted on the inner surface. Material flowing past the sensor causes a deflection, the magnitude of which is quantified by the FBGs to characterize the in-process material real-time.

Figure 1: Drag Fource Flow Sensors (top) Use FBGs (bottom) to Measure, with High Sensitivity, the Local Forces Associated with Moving Powders
Figure 1: Drag Fource Flow Sensors (top) Use FBGs (bottom) to Measure, with High Sensitivity, the Local Forces Associated with Moving Powders - ISPE Pharmaceutical Engineering
Source
Source: Lenterra, Inc. Reprinted with permission
Figure 1: Drag Fource Flow Sensors (top) Use FBGs (bottom) to Measure, with High Sensitivity, the Local Forces Associated with Moving Powders - ISPE Pharmaceutical Engineering
Source
Source: Lenterra, Inc. Reprinted with permission


An FBG is a periodic structure of varying refractive index embedded in the core of an optical fiber. It reflects light traveling through the fiber at a wavelength that depends on its grating constant and refractive index. These two parameters are influenced by ultra-low levels of strain in the FBG region and by temperature (between –20°F and 200°F).

Using two FBGs opposite one another differentiates wavelength changes associated with deflection of the probe from changes associated with temperature to determine localized flow forces. The resulting raw-flow-force data are usefully converted into force pulse magnitude (FPM) measurements, where FPM is the difference between the maximum and minimum forces in a defined period. As a differential measurement, FPM is always positive and unaffected by baseline drift, making it a robust parameter for process monitoring.

The best PAT answers to an increasingly well-understood list of requirements that include issues relating to the process interface—ease of installation plus cleaning, reliability, and safety. It also assesses the value of the data: Is the measurement frequency sufficiently high? Are the data relevant? Such criteria are helpful in assessing the potential of new PAT. 

Practicalities of measurement

Drag force flow sensors are typically around 3 millimeters in diameter, a small footprint that creates minimal flow disruption and a low risk of fouling. The instrumentation has a chemically resistant, easy-to-sterilize stainless steel construction, presents no ignition hazard, and is not subject to electromagnetic interference.

The dual-FBG design makes the technique self-calibrating with respect to temperature, enhancing data robustness. Since measurements can be recorded at a frequency up to 500 hertz, drag force flow sensors offer precise temporal resolution. The technique is highly sensitive; deflections in the region of just one micron are reproducibly detectable (forces of ~ 0.5 milliNewtons), which translates into the ability to characterize particles with a density as low as 0.15 grams per cubic centimeter, for example.

In summary, the technique can provide direct and precise measurements at frequencies that match the dynamics of even rapidly changing processes, and is inherently well suited to in-line implementation. But what are the measurements’ relevance and value in terms of improving process performance? 

DATA RELEVANCE

The terms “powder” and “particles”  are often used interchangeably. Powders, however, are bulk assemblies of particles, liquid (usually water), and gas (typically air). Measuring particle properties is not the same as measuring bulk powder properties. PAT is well-established for particle-size measurement, and there are often direct links between the particle size of an active ingredient and, for example, its rate of dissolution/bioavailability. This may encourage the use of such technology.

Particle size, however, is just one of many variables that influence powder flowability. This in turn can affect aspects of process performance such as blend time, fill uniformity, and tableting speed. If PAT is being considered to control these aspects of performance, then measuring particle size, or indeed any other particle property, is an inherently limited approach.

Considering the measurement of bulk powder properties, the issue often becomes one of interpretation and secure correlation with critical quality attributes (CQAs) of the product. This can compromise the application of potential PATs for high-shear wet granulation (HSWG) monitoring, such as acoustic, microwave, stress, and vibration measurements and power drawn by the agitator.1 These techniques enable continuous measurement, but it can be difficult in some instances to interpret the resulting data to exert effective control, because that data is affected by a number of variables.

A notable success in developing robust relationships between powder properties and CQAs has been the demonstration of direct correlations between the dynamic flow properties of granules and the hardness of tablets produced from them.2 Dynamic flow properties are determined using a powder rheometer to measure the force and torque acting on a helical blade as it rotates through a sample of the powder. Though this at-line technique is significantly different from drag force flow measurement, the fundamental approach of measuring the forces associated with a bulk powder in motion has certain similarities. The two techniques have been shown to produce comparable data in HSWG trials carried out by a major pharmaceutical company.3

In these trials, the water-addition step was shown to trigger a significant rise in the basic flow energy (a dynamic flow property) or FPM associated with movement of the granulating mass, with both parameters providing a secure basis for end point detection. Both techniques, furthermore, clearly differentiated granules produced with different levels of binder: 1%, 3%, and 5% hydroxypropyl cellulose. Higher levels of binder are associated with stronger granule formation and high flow energy/FPM values.

These early correlations with dynamic powder properties, which have proven process relevance across a range of unit operations, indicate that though drag force flow measurement is still in its infancy, it may prove to be a PAT that is more tractable to correlation with process performance than others. As such, it could prove a valuable monitoring solution for blending, mixing, agglomeration, and many other powder-handling applications. A case study further illustrates the capability and potential of the technique. 

CASE STUDY

Investigating binder distribution using drag force flow measurements

The effect of binder viscosity on blending performance was investigated using Binder A, viscosity 0.001 pascal second (Pa.s) and Binder B, viscosity 100 Pa.s. Following 20 seconds of dry mixing, 1% or 3% by weight of binder solution was added to an excipient bulk, and blending was carried out for a further period of 300 seconds. Excipient mass and shear rate were kept constant throughout.

Comparing the two sets of data gathered for Binder A (top two traces, Figure 2) increasing binder concentration reduces the time required to reach content uniformity, the point at which FPM becomes effectively constant. Comparing the results for Binder A with those for Binder B indicates that a lower concentration of the less viscous binder (A) is required to achieve a uniform blend. In fact, at low concentration (1%), Binder B does not appear to reach a state of uniform dispersion, forming instead relatively stable agglomerates that cause spikes in the FPM trace. This poor dispersion can be attributed to high viscosity. Another notable conclusion that can be drawn from the 1% Binder B trace is that the sensor can clearly differentiate a formulation containing modest levels of binder from the excipient alone (black trace).

  • 1Hansuld, E.M. and L. Briens. 2014. “A Review of Monitoring Methods for Pharmaceutical Wet Granulation.” International Journal of Pharmaceutics 472, 1-2:192-201.
  • 2Freeman, T. “In Pursuit of Wet Granulation Optimization.” Pharmaceutical Manufacturing (21 March 2014). http://www.pharmamanufacturing.com/articles/2014/in-pursuit-of-wet-granulation-optimization
  • 3Narang, A. S., et al. “Process Analytical Technology for High Shear Wet Granulation: Wet Mass Consistency Reported by In-Line Drag Flow Force Sensor Is Consistent with Powder Rheology Measured by At-Line FT4 Powder Rheometer.” Journal of Pharmaceutical Sciences 105, no. 1 (January 2016): 185–187.
Binder A 1 - ISPE Pharmaceutical Engineering
Binder A 3
Binder B 1 - ISPE Pharmaceutical Engineering
Figure 2: FPM Measurements Differentiate the Performance of Binder A and Biner B, Showing the Blending Times Required to Achieve a Uniform Dispersion, Where Feasible
Figure 2: FPM Measurements Differentiate the Performance of Binder A and Biner B, Showing the Blending Times Required to Achieve a Uniform Dispersion, Where Feasible - ISPE Pharmaceutical Engineering

CONCLUSION

Identifying optimal PAT for powder processing remains an ongoing task, with the drive toward continuous manufacture intensifying requirements for smarter solutions. New in-line technology for real-time powder-flow characterization offers considerable potential within this context and opportunities to boost the efficiency of process development, scale-up, monitoring, and control.

Not a Member Yet?

To continue reading this article and to take advantage of full access to Pharmaceutical Engineering magazine articles, technical reports, white papers and exclusive content on the latest pharmaceutical engineering news, join ISPE today. In addition to exclusive access to all of the content in Pharmaceutical Engineering magazine, you will get online access to 24 ISPE Good Practice Guides, exclusive networking events, regulatory resources, Communities of Practice, and more.